Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Fisioter. Mov. (Online) ; 35(spe): e35601, 2022. tab
Article in English | LILACS | ID: biblio-1404815

ABSTRACT

Abstract Introduction: The climacteric is one of the transition periods in the life cycle of women between the reproductive and non-reproductive phase, and it is characterized by various metabolic, psychological and social changes, either by psychic disorders or sexual dysfunctions promoting changes in quality of life. Objective: To analyze the repercussions of electrical stimulation on quality of life, lubrication and myoelectric activity of pelvic floor muscles in postmenopausal women. Methods: This was a pilot study in which the sample consisted of ten menopausal volunteers aged 48-60 years. We used the Female Sexual Function Index questionnaire to determine the improvement in lubrication and the WHOQOL-BREF questionnaire to assess quality of life. The pelvic floor muscles were evaluated by electromyography with an intracavitary electrode. The protocol used was: phasic contraction evaluated by three contractions of two seconds and six of rest; three tonic contractions for ten seconds with ten-second rest; and endurance for thirty seconds. The intervention was performed by another researcher, through circulatory stimulation with the Dualpex 961 Quark®. Results: Electromyography after circulatory stimulation showed statistically significant results with an increase in Fast Fourier Transform in tonic and phasic contractions, obtaining a positive effect on the perception and awareness of contractions due to increased blood flow. Also, there was improvement in lubrication and quality of life in all areas. Conclusion: Circulatory stimulation had repercussions on pelvic floor muscles in menopausal women in both muscle physiology and lubrication, with an influence on the quality of life of volunteers.


Resumo Introdução: O climatério constitui um dos períodos de transição no ciclo vital da mulher entre a fase reprodutiva e a não reprodutiva, caracterizado por várias alterações metabólicas e psicológicas, seja por distúrbios psíquicos ou disfunções sexuais, promovendo alterações na qualidade de vida. Objetivo: Analisar as repercussões da eletroestimulação na qualidade de vida, lubrificação e atividade mioelétrica dos músculos do assoalho pélvico em mulheres menopausadas. Métodos: Trata-se de um estudo piloto no qual a amostra foi composta por dez voluntárias em menopausa com idade entre 48 e 60 anos. Para avaliar a melhora da lubrificação foi utilizado o questionário Female Sexual Function Index. Quanto à qualidade de vida, utilizou-se o questionário WHOQOL-bref. Já para a avaliação dos músculos do assoalho pélvico, utilizou-se a eletromiografia com eletrodo intracavitário. O protocolo utilizado foi: contração fásica avaliada por três contrações de dois segundos e seis de repouso; três contrações tônicas sustentadas por dez segundos com repouso de dez segundos; endurance durante trinta segundos. A intervenção foi realizada por outra pesquisadora, através de estimulação circulatória com o aparelho Dualpex 961 Quark®. Resultados: A eletromiografia pós-estimulação circulatória obteve resultados significativos, com aumento na Fast Fourier Transform nas contrações tônicas e fásicas, obtendo efeito positivo na percepção e conscientização das contrações devido ao aumento do fluxo sanguíneo. Houve, também, melhora na lubrificação e na qualidade de vida em todos os domínios. Conclusão: A estimulação circulatória apresentou repercussões nos músculos do assoalho pélvico em mulheres menopausadas tanto na fisiologia muscular quanto na lubrificação, influenciando a qualidade de vida das voluntárias.


Subject(s)
Humans , Female , Middle Aged , Climacteric , Electric Stimulation , Electromyography , Quality of Life , Menopause
2.
Dental press j. orthod. (Impr.) ; 24(2): 66-72, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1001855

ABSTRACT

Abstract Objective: This study investigated the effect of the condition of lubrication on the friction between brackets and NiTi archwires of different rounded cross-sections. Methods: Brackets (Roth, GAC) were affixed to a device connected to a universal testing machine into which segments of archwire were placed (NiTi, Nitinol, GAC) with cross-sections of 0.012-in, 0.016-in and 0.020-in. Once the wire was in the bracket slot, the following lubricants were applied: human saliva (HS: positive control), distilled water (DI), mucin-based (MUC) or carboxymethylcellulose-based (CMC) artificial saliva. In the negative control group, no lubricant was used. The combination between the wire cross-sections and the lubrication condition generated 15 groups with 15 samples each. Data were submitted to two-way analysis of variance and Tukey's test. Results: There was no significant interaction between the wire cross-section and the condition of lubrication (p= 0.901). Irrespective of whether lubricants were used or not, there was a significant increase in friction with an increase in the cross-section of the wire (p< 0.001). For any wire, the group tested in the presence of MUC was not different from that in which HS was applied. On the other hand, when the application of lubricants was suppressed, significantly higher friction values were observed. The CMC group and the DI group demonstrated intermediate behavior. Conclusions: Friction increased with the increase of the cross-section of the NiTi archwire, but regardless of the archwire, friction with MUC artificial saliva was similar to that of HS and lower than in dry conditions.


Resumo Objetivo: este estudo investigou o efeito das condições de lubrificação no atrito entre braquetes e fios de NiTi de diferentes secções transversais. Métodos: os braquetes (Roth, GAC) foram fixados a um dispositivo conectado a uma máquina de ensaio universal, que recebeu segmentos de fio de NiTi (Nitinol, GAC) com secções de 0,012"; 0,016" ou 0,020". Após o fio ter sido instalado no slot do braquete, aplicou-se um dos seguintes lubrificantes: saliva humana (SH: controle positivo), água destilada (AD) ou saliva artificial à base de mucina (MUC) ou de carboximetilcelulose (CMC). No grupo controle negativo, nenhum lubrificante foi utilizado. As combinações entre as secções dos fios e as condições de lubrificação geraram 15 grupos, com 15 amostras cada. Os dados foram submetidos à análise de variância a dois critérios e ao teste de Tukey. Resultados: não houve interação significativa entre a secção do fio e a condição de lubrificação (p = 0,901). Independentemente de ter sido utilizado ou não lubrificante, observou-se elevação significativa do atrito com o aumento da secção transversal do fio (p < 0,001). Para qualquer um dos fios, o grupo testado na presença de MUC não diferiu daquele em que se aplicou SH. Por outro lado, quando suprimiu-se os lubrificantes, constatou-se atrito significativamente mais elevado. Os grupos CMC e AD demonstraram comportamento intermediário. Conclusões: o atrito se elevou com o aumento da secção transversal dos fios de NiTi, mas a despeito do fio, o atrito com a saliva à base de MUC foi similar àquele com a SH e menor do que sob condição a seco.


Subject(s)
Humans , Orthodontic Brackets , Orthodontic Wires , Stainless Steel , Surface Properties , Titanium , Materials Testing , Orthodontic Appliance Design , Friction , Dental Alloys
3.
São Paulo; s.n; 2015. 125 p. ilus, tab. (BR).
Thesis in Portuguese | LILACS | ID: lil-775982

ABSTRACT

O esmalte dental é o tecido mineralizado mais duro do corpo humano; apesar disto, seu desgaste é um problema muito comum. Este pode estar associado aos processos de envelhecimento, ou ainda, ser encontrado em indivíduos jovens, como consequência de atividades parafuncionais, por exemplo, atrição dental. Este tipo de dano pode resultar em prejuízo da função mastigatória e em diminuição da qualidade de vida. Por isto, o desgaste do esmalte dental tem sido objeto de muitos estudos, embora poucos tenham utilizado conceitos tribológicos. Não foi encontrado nenhum estudo que explorasse o desgaste de esmalte e seus micromecanismos oriundos do deslizamento alternado de incisivo contra incisivo, configuração que mais se aproxima do tribossistema real de atrição. O presente estudo tem por objeto investigar o desgaste e seus mecanismos em pares deslizantes de esmalte incisal (configuração pino-plano), selecionados por seus similares valores de dureza e de tenacidade à fratura, submetidos a diferentes cargas normais e lubrificações do meio. Incisivos bovinos foram ensaiados em deslizamento alternado sob duas cargas normais (8 N e 16 N) e quatro modos de lubrificação: saliva natural; saliva artificial; gel lubrificante oral (Oralbalance!, Biotène); e grupo controle sem lubrificação (seco)...


Enamel is the hardest mineralized tissue in the human body; despite that, the enamel wear is a very common problem. The wear damage can be related to aging processes or also be found in young people as a result of parafunctional activities, for example, dental attrition. This type of damage can result in loss of masticatory function and decreased quality of life. Therefore, the wear of the enamel has been the subject of many studies, although few have used tribological concepts. The wear mechanisms of reciprocating sliding pairs from incisor against incisor have not been reported in the literature, this configuration is the one that is closest to the real tribosystem of attrition. The present study aims to investigate the wear behavior and the related mechanisms in reciprocating sliding pairs of incisal enamel (pin-on-flat configuration), selected for their similar hardness and fracture toughness values, with different applied normal loads and lubrication conditions. Bovine incisors were tested in reciprocating sliding with different applied normal loads (8 N and 16 N) and four lubrication conditions: natural saliva; artificial saliva; oral gel lubricant (Oralbalance!, Biotène); and control group (dry). During tests, the friction curves were recorded...


Subject(s)
Humans , Tooth Abrasion/complications , Tooth Abrasion/diagnosis , Dental Materials , Dental Enamel/injuries , Lubrication/methods , Microscopy, Electron, Scanning/methods
4.
ImplantNews ; 9(6): 873-882, 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-850987

ABSTRACT

O objetivo deste estudo foi investigar a influência de um lubrificante líquido nos valores de torque/destorque de parafusos de pilar e cilindro protético em um sistema de hexágono externo; 20 implantes (3,75 mm x 13 mm) foram usados neste estudo. O longo eixo de cada implante foi colocado em anéis de PVC e fixado com resina acrílica incolor autopolimerizável. Na primeira etapa, pilares tipo Microscone foram apertados com 32 Ncm. Quatro grupos com cinco amostras cada foram utilizados: G1 (sem lubrificante, sem reaperto), G2 (sem lubrificante, com reaperto), G3 (com lubrificante, sem reaperto) e G4 (com lubrificante, com reaperto). Na segunda etapa, cilindros protéticos de Ti e Co-Cr foram apertados até 10 Ncm. Quatro grupos com cinco amostras cada foram utilizados: G1 (sem lubrificante, cilindro Ti), G2 (sem lubrificante, cilindro Co-Cr), G3 (com lubrificante, cilindro Ti) e G4 (com lubrificante, cilindro Co-Cr). O teste Anova dois critérios (nível de significância 5%) foi usado em ambas as etapas para comparar os valores entre os grupos. Os testes Kruskal-Wallis e Tukey foram usados para investigar o efeito dos reapertos nos valores finais de destorque em cada etapa. Os resultados mostraram que a interação entre lubrificante e reaperto não foi significativa na primeira etapa, mas diferenças foram vistas da segunda à quinta repetição de aperto na primeira etapa. Da mesma forma, não houve interação entre lubrificante e cilindro e os reapertos sequenciais não foram significativos na segunda etapa. Concluiu-se que o uso de um lubrificante pode aumentar o torque nos parafusos protéticos, mas não nos parafusos dos pilares.


The purpose of this study was to investigate the influence of a liquid lubricant on abutment and prosthetic screw torque/detorque values in an external hex system. Twenty dental implants (3.75 mm-diameter x 13 mm-length) were used in this study. The implant long axis was embedded into PVC rings and secured with clear autopolymerizing acrylic resin. In the first phase, Microscone-like abutments were tightened to 32 Ncm. Four groups of five samples each were made: G1 (no lubricant, no retightening), G2 (no lubricant, retightening), G3 (lubricant, no retightening), and G4 (lubricant, retightening). In the second phase, Ti and Co-Cr prosthetic cylinders were tightened to 10 Ncm. Four groups of five samples each were made: G1 (no lubricant, Ti cylinder), G2 (no lubricant, Co-Cr cylinder), G3 (lubricant, Ti cylinder) and G4 (lubricant, Co-Cr cylinder). Two-way Anova tests (5% significance level) were performed in both phases to compare values among groups. Also, the Kruskal-Wallis and Tukey tests were performed to investigate the effect of repeated tightening on final detorque values in each phase. Results demonstrated that the interaction between lubricant and retightening was not statistically significant for the first phase, but differences were identified between the 2nd and 5th tightening repetition. In the same way, interaction between lubricant and cylinder did not demonstrate significant results, and no differences were seen among repeated tightening in the second phase. It can be concluded that the use of a lubricant can increase torque on prosthetic but not abutment screws.


Subject(s)
Dental Implants , Torque , Biomechanical Phenomena
5.
Araraquara; s.n; 2000. 121 p. ilus, tab.
Thesis in Portuguese | BBO, LILACS | ID: biblio-864048

ABSTRACT

O objetivo deste estudo é avaliar ao Microscópio Eletrônico de Varredura (MEV) e Rugosímetro o efeito da afiação com e sem lubrificante utilizando três tipos de pedras de afiar sobre o ângulo de corte das curetas e o efeito sobre a superfície radicular instrumentada. Para isso foram selecionadas 24 curetas novas marca Neumar e distribuídas aleatoriamente em 8 grupos experimentais: curetas novas, curtas sem corte, curetas afiadas com pedras de Arkansas, Óxido de Alumínio e Carborundum com e sem lubrificante. Posteriormente as lâminas das curetas foram separadas das hastes e fotografadas ao MEV onde obtiveram-se fotomicrografias que foram avaliadas por 3 examinadores diferentes designando-se valores para cada foto de acordo ao Índice Modificado do Ângulo de Corte, da melhor a pior condição encontrada. Na segunda parte da pesquisa repetiu-se todos os passos da primeira fase, com a diferença que as lâminas não foram separadas das hastes, efetuando-se a instrumentação radicular sobre dentes provenientes de um bando de dentes pré-existentes de acordo com cada grupo experimental, procedimento realizado com um aparelho padronizador desenhado especificamente para este estudo. Posteriormente as áreas instumentadas foram separadas para análise ao Rugosimetro e logo tomadas fotomicrografadas ao MEV que foram avaliadas por 3 examinadores diferentes designando-se valores para cada foto de acordo ao Índice Modificado de Irregularidade Superficial, da melhor a pior condição encontrada. Os resultados obtidos foram enviados para análise estatística. Conforme os resultados, conclui-se: o lubrificante não exerceu influência significante sobre o ângulo de corte e a superfície radicular, sendo que o fator tipo de pedra exerceu um efeito direto sobre o ângulo de corte e a superfície radicular. As pedras de Arkansas com e sem lubrificante tiveram os melhores resultados, as pedras de Óxido de Alumínio os piores e as pedras de Carborundum com e sem lubrificante uma posição intermediária entre as duas anteriores, em termos de lisura do ângulo de corte e superfície radicular. Precisa-se de estudos adicionais para estabelecer o efeito lubrificante em termos de lisura do ângulo de corte e a superfície radicular


The purpose of this work was the assessment on Scanning Electron Microscope (SEM) and Perfilometer the effect of sharpen with three kinds of sharpen stones using or not lubricant over curet's cutting edges and the effect over instrumentated root surface. Twenty-four Neumar curets were selected and ramdomly distributes in eight experimental groups: new curets, dull curets, resharpened curtes with Arkansas stone, Aluminium Oxide and Carborundum with and without lubricant. Subsequently, the curet blades were separated from the handle and photographed on SEM. The photographs were examinated by three diferent examiners and the values given, according to the index of cutting edge, from better to worse were found. In the second part of the work, all the steps of the first phase were repeated except that the blades were not separated from the handle. The instrumentation of the experimental groups were done with the patterned apparatus on root segments from a teeth bank source. The instrumented areas were separated and a Perfilometer analysis and SEM photographs were made and analysed by the examiners. It was conclude from the statistical analysis that the lubricant did not highly influence the cutting edge and root surface. The type of stone influenced directly the cutting edge and root surface. The Arkansas's stone with and without lubricant show the highest result while the Aluminium Oxide stone the lowest. The carborundum stones with and without lubricant show intermediated results. Further studies are necessary to stablish the lubricant effecting on cutting edge smoothness and root surface


Subject(s)
Statistics, Nonparametric , Dental Instruments , Lubrication , Microscopy, Electron, Scanning , Dental Scaling
SELECTION OF CITATIONS
SEARCH DETAIL